Skip to main content

Table 1 HPLC operating condition for vitamin thiamin, riboflavin, and niacin analyses

From: Comparison of the retention rates of thiamin, riboflavin, and niacin between normal and high-oleic peanuts after roasting

 

Thiamin and Niacin

Riboflavin

Instrument

Agilent 1100 series

Agilent 1100 series

Column

YMC-Pack ODS AM (250 mm × 4.6 mm, 5 μm)

YMC PRO RS C18 (250 mm × 4.6 mm, 5 μm)

Column temp.

40 °C

40 °C

Detector

Diode array detector (270 nm)

FLD (Ex = 445 nm, Em = 530 nm)

Flow rate

0.8 mL/min

0.8 mL/min

Mobile phase

A: 5 mM sodium 1-hexanesulfonate (acetic acid 7.5 mL + triethylamine 0.2 mL/1 L)

10 mM NaH2PO4 (pH 5.5): MeOH = 75:25 (v/v)

B: 100% MeOH

 

Gradient profile

0 min: A 100%

Isocratic

8 min: A 100%

 

20 min: A 75% + B 25%

 

30 min: A 55% + B 45%

 

31 min: A 100%

 

45 min: A 100%

 

Injection volume

20 μL

20 μL